Our Turbovac series are the ideal systems for environmental remediation work that will handle heavy sludge, slurries and liquid waste materials without compromise. With its cyclonic filtration technology, airflow ratings of 1,800 CFM to 5,500 CFM and powered with 28" Hg of vacuum, this system is your solution to most complex hazardous and non-hazardous waste removal, transportation and remediation problems.

Model:

2627

3827

5327

Noise Level 9 ft. distance: 92 dbA 95 dbA 95 dbA
Maximum CFM Blower: 2600 3800 5300
CFM @ 15”: 1438 2250 4141
Maximum Vacuum: 27" Hg 27" Hg
Maximum Pressure PSI: 15 15
Clear CA: 172" 190" 200 "
Required Front Axle: 18,000 lb. 20,000 lb. 20,000 lb.
Required Rear Axle: 46,000 lb. 46,000 lb.
Horsepower: 300 350 425
Transmission requirements: Overdrive w/cooler Overdrive w/cooler Overdrive w/cooler

Tank Material: Head: 0.3125” SA516-70
Shell: 0.3125” SA516-70
Diameter: 78"
Blower: Airflow: 2600-5300 CFM Max Vacuum: 28”Hg
Off Loading Pump: Mode: PM100 Pressure: 15 PSI
Blower Drive:

Model: Hayes Dana transfer case or belt drive from 8 bolt PTO

Isolation Valve: Single or dual 8” air operated butterfly valves
Shut-off: Primary: 12” SS float ball assembly with 8” rubber seat
Filtration: Single or dual 8” cyclone assemblies with 100 micron blower inlet filter
Liquid Level Indicator: SS rotary float gauge with 6” SS float ball and sight cage assembly
Blower Piping: Single or dual 8” diameter with quick disconnect rubber boot assembly. 6” manual vacuum relief valve with 10” or 12” check valve
Blower Silencers: Intake: 10” or 12” absorption
Exhaust: 10” or 12” chamber
Valves: Suction/Discharge: 6” Betts air operated/spring closing
Dump System: Hydraulic: 30 ton capacity 120” stroke, 3 stage
Rear Door: Hydraulic: Full opening with 6 heavy duty wing clamps
Vibrator: Hydraulic: Mounted on the bottom of the tank